Home/ Products/ QC & Analysis/ Nanoparticle Size & Zeta Potential Analyzer (DLS)
Nanoparticle Size & Zeta Potential Analyzer (DLS)
QC & Analysis

Nanoparticle Size & Zeta Potential Analyzer (DLS)

Benchtop light-scattering analyzer combining DLS, ELS/PALS, SLS, and transmittance detection in one platform - simultaneous particle size (0.3 nm-15 um), PDI, zeta potential, and molecular weight for LNP, liposome, exosome, protein, and polymer QC.

Catalog no. DLS-ZETA · Ships with certificate of analysis

For Research Use Only
Request Sample COA

Overview

At a Glance

  • Integrated light-scattering platform combining DLS (size), ELS/PALS (zeta potential), SLS (molecular weight), and transmittance detection in one benchtop instrument
  • Size by Brownian motion: scattering-intensity fluctuations are autocorrelated to obtain the diffusion coefficient, then converted to hydrodynamic diameter via the Stokes-Einstein equation
  • Zeta by phase-analysis electrophoretic light scattering (PALS): electrophoretic mobility of charged particles in an applied field is converted to zeta potential
  • One run delivers the core LNP QC triad: hydrodynamic size, PDI, and zeta potential - the two release-critical attributes tracked alongside encapsulation efficiency

Key Features

  • Wide size range: 0.3 nm to 15 um hydrodynamic diameter, covering LNP, liposome, exosome, protein, and polymer systems
  • Multi-angle detection (173 deg backscatter + 90 deg + 11.2 deg): high-concentration samples measured directly by backscatter; forward angles cover low-concentration and large-particle work
  • Tiny sample requirement: minimum ~3 uL with the low-volume cuvette; standard measurements ~1 mL
  • Concentration tolerance up to 40% w/v - dilute-averse formulations can often be measured as-is
  • Trend analysis: size / zeta tracked vs. temperature, time, or pH, with transition points such as Tm reported automatically
  • Broad temperature control (-15 C to 120 C) for stability studies and thermal scans
  • Flexible algorithms: Cumulants, CONTIN, and NNLS for size distribution analysis

Specifications (manufacturer data)

ParameterSpecification
PrinciplesDLS (size), ELS/PALS (zeta potential), SLS (molecular weight), transmittance
Size range0.3 nm - 15 um
Sample volumeMinimum 3 uL; typical ~1 mL
Detection angles173 deg + 90 deg + 11.2 deg (multi-angle)
Sample concentrationup to 40% w/v
AlgorithmsCumulants, CONTIN, NNLS
OutputsHydrodynamic diameter (Dh), PDI, diffusion coefficient, zeta potential & distribution, electrophoretic mobility
Molecular weight range342 Da - 2 x 10^7 Da
Conductivity range0 to >=270 mS/cm
Temperature control-15 C to 120 C
Laser sourceSolid-state laser, ~671 nm (optional wavelengths available)
Trend analysisSize / zeta vs. temperature, time, pH; transition point (Tm) determination
Use statementFor Research Use Only (RUO) - not for clinical diagnosis or therapy

Sample Handling Notes

  • Dust and aggregates destroy DLS data: samples must be well dispersed, free of bubbles, and free of large particles - filter or centrifuge to remove dust where appropriate
  • Use the low-volume cuvette for precious samples; use the 173 deg backscatter angle for high-concentration or turbid samples
  • Zeta measurements require the dedicated electrode cell: watch medium conductivity and follow the cell's rated conductivity range
  • Trend runs (temperature / pH titration) are the fastest way to assess formulation stability and colloidal robustness

Applications

  • LNP and liposome QC: size, PDI, and zeta potential release testing - the core physical attributes for LNP formulation programs
  • Formulation screening and comparability studies across lipid compositions and process changes
  • Stability and stress studies: size / zeta vs. temperature, pH, and time, with Tm detection
  • Colloidal stability judgment ahead of storage, shipping, and administration studies
  • General nanoparticle characterization: exosomes, proteins, polymers, emulsions in chemistry, biotech, pharma, food, and materials labs

Research Use Only

For Research Use Only. The instrument and its documentation do not reference medical or diagnostic use.

Ordering & Documentation

  • Configurations, optional accessories (low-volume cuvettes, electrode cells, titrator), and pricing are confirmed per inquiry
  • Specifications, documentation, and lead times are verified per order - Send us an inquiry and we will respond with a detailed quotation.
ProductNanoparticle Size & Zeta Potential Analyzer (DLS)
Catalog no.DLS-ZETA
CategoryQC & Analysis
DocumentationCertificate of analysis provided with every lot
Intended useFor Research Use Only (RUO). Not for diagnostic or therapeutic use.

Related products