Home/ Products/ LNP Formulation/ PES Ultrafiltration Centrifugal Devices
PES Ultrafiltration Centrifugal Devices
LNP Formulation

PES Ultrafiltration Centrifugal Devices

Single-use PES-membrane spin concentrators for rapid concentration, desalting and buffer exchange of LNPs, exosomes, proteins and nucleic acids — 3 volumes, 6 MWCOs, >85–95% typical recovery.

Catalog no. UF-PES-0.5 / 4 / 15 (3K / 5K / 10K / 30K / 50K / 100K) · Ships with certificate of analysis

For Research Use Only
Request Sample COA

Overview

At a Glance

Single-use ultrafiltration spin devices with a hydrophilic modified PES (polyethersulfone) membrane. Centrifugal force drives water and small molecules through the membrane into the collection tube while retaining macromolecules — proteins, nucleic acids, exosomes, viral particles and LNPs — in the sample chamber. Concentrate, desalt or buffer-exchange in 15–40 minutes instead of overnight dialysis.

Key Features

  • Fast, three-step workflow: load, spin, recover — replaces overnight dialysis bags
  • High recovery: >85–95% typical, thanks to a low-binding hydrophilic PES membrane
  • Flexible formats: 3 device volumes x 6 MWCOs cover proteins, nucleic acids, exosomes, viral particles and LNPs
  • Broad chemical compatibility: pH 1–14; resistant to acids, bases, organic solvents and denaturants
  • Universal fit: standard 1.5/2 mL, 15 mL and 50 mL rotors — no dedicated equipment required
  • Over-spin protection: physical dead-stop volume prevents the membrane from spinning to dryness; printed graduations for at-a-glance volume reading

Device Specifications

ParameterSpecification
Membrane materialModified PES, hydrophilic, low protein/nucleic acid binding
MWCO options3 / 5 / 10 / 30 / 50 / 100 kDa
Device volumes0.5 / 4 / 15 mL
Typical recovery>85–95% (MWCO- and sample-dependent)
Concentration factor10–50x
pH range1–14
Maximum RCF4,000 x g (higher force increases membrane breakthrough risk)
SterilityNon-sterile, single-use
Intended useFor Research Use Only

Volume Formats

VolumeMembrane area
0.5 mL0.9 cm2
4 mL3.4 cm2
15 mL9.5 cm2

MWCO Selection Guide

MWCOProteins (MW)
3 kDa~6–20 kDa
5 kDa~15–45 kDa
10 kDa~30–90 kDa
30 kDa~90–180 kDa
50 kDa~150–300 kDa
100 kDa>300 kDa

Rule of thumb: select an MWCO at least 3x smaller than your target molecule's molecular weight (e.g., for a 30 kDa target, choose a 10 kDa device) for secure retention and maximum recovery.

Typical Retention & Recovery (15 mL devices, 4,000 x g)

MWCOTest sample
3 kDaCytochrome c (12.4 kDa)
5 kDaLysozyme (14 kDa)
10 kDaLysozyme (14 kDa)
30 kDaBSA (66 kDa)
50 kDaBSA (66 kDa)
100 kDaIgG (150 kDa)

Applications

  • LNP / liposome concentration, buffer exchange and removal of free components (untethered lipids, free nucleic acid) ahead of QC or downstream use
  • Exosome, viral particle and nanoparticle concentration and purification
  • Protein, antibody and enzyme concentration and desalting
  • Nucleic acid fragment concentration and clean-up
  • Sample prep before HPLC or analytical QC; macromolecule recovery from culture media and lysates

Handling Notes

  • Non-sterile, single-use. Do not autoclave or sterilize by UV or alcohol immersion. For sterile workflows, devices may be treated with 70% ethanol before use, or contact us regarding sterile-packaged options.
  • As with any ultrafiltration membrane, trace breakthrough can occur — keep the filtrate until recovery in the retentate is confirmed.
  • The membrane contains a trace glycerol preservative; rinse with working buffer before processing sensitive samples.
  • Balance the rotor carefully and stay within the rated RCF (max 4,000 x g). Spin-down is slower at 4 C than at room temperature.

Research Use Only

For Research Use Only. Not for clinical, diagnostic or therapeutic use in humans.

Ordering & Documentation

Three volumes (0.5 / 4 / 15 mL) x six MWCOs (3–100 kDa). Available configurations, COA, MSDS, ISO documentation, FOB pricing, MOQ and lead time are confirmed per inquiry: Send us an inquiry

ProductPES Ultrafiltration Centrifugal Devices
Catalog no.UF-PES-0.5 / 4 / 15 (3K / 5K / 10K / 30K / 50K / 100K)
CategoryLNP Formulation
DocumentationCertificate of analysis provided with every lot
Intended useFor Research Use Only (RUO). Not for diagnostic or therapeutic use.

Related products

Get a quote for PES Ultrafiltration Centrifugal Devices

Specs, pricing, lead time and shipping options — usually within one business day.

Ask AI